The most important task of hydropower construction Xiaobian Weapon Super practical concealed project decoration

<

The circuit is a covert project for home improvement. If something goes wrong afterwards, it will be very troublesome to repair it. In this section, we will introduce the precautions for hydropower construction.


Yilibao Ceramics

There are two main reasons for the most problems in hydropower construction. First, electricians do not have relevant certificates at all, and they have not been subjected to formal electrician operation and learning, resulting in non-standard construction; the other is to violate the rules of circuit construction by cutting corners and gaining more benefits. The owner must pay attention to the uniform color of electrical wires in the circuit construction. This is the most problematic. The second is the damage of the cassette and the failure to lock the mother. Finally, there is suspicion that the layout is irrational and there is a detour to increase the length.

It is not only the quality of the telephone line that must be guaranteed. In the selection of switches and sockets, it is better to choose brand products or products with safety certification marks, and they should be purchased in large building materials stores. Do not try to buy in some hardware stores. There are no manufacturers or products with no certification mark to avoid the risk of counterfeit products. In wet environments such as bathrooms, special moisture-proof sockets must be used. Electric appliances such as air conditioners with large power consumption must be routed separately and use special sockets.

In the process of new house decoration, many people often pay attention to the quality and safety performance of carpentry and tile work, ignoring the circuit installation. As everyone knows, the safety performance of these concealed projects is even more important. Once rework is done, it makes everyone feel uncomfortable and does not say anything about it. The engineering movements are large, time-consuming, labor-intensive, and costly.

Precautions for circuit construction in various parts:

Ceiling: The correct construction method for the protection of the lighting line on the ceiling is to pass the lighting wire through the yellow wax tube and then buried in the shallow groove above the ceiling. In this photo, it is a wrong practice for the top lighting line electrician to wrap in insulating tape, and the insulating tape becomes sticky and then softens after a long time. It is not safe to bury it in the wall, and it does not protect the wire at all.

In the wall: The wires embedded in the wall must be protected by pipes, and the cassettes for installing the panels must be intact and secure in order to protect the wires inside. In the picture, there is a line without wires, and the electrician breaks the cassette when it is threaded. Readers must carefully check if they are doing decoration. Do not allow such a cassette to be installed in your home.

Flooring: Pay attention to floor wiring. In the construction of the wiring, if the ground is floored, whether composite or solid wood (bamboo), experts suggest that citizens should put the wire as far as possible on the wall foot behind the skirting board, only in the wall plug, door or wall, etc. A small pipe is buried behind the skirting board. There can be no dead curve in the middle of the line tube. Leave the lead wire in the tube. Wait until the floor is finished but the skirting board is not yet installed. After installing the skirting board, it will not see any traces of the traces, it is very beautiful. Since the flooring is laid in the final stage of the renovation work, when the flooring is laid, it can be effectively prevented from causing accidental damage to the wire during the long construction period. When the public wants to change lanes or add lines, it is very convenient to remove the skirting boards for construction. Because the line pipe does not go under the floor, it is not necessary to cut off the wooden keel underneath the solid wood (bamboo) floor (except when the line pipe and the wooden keel move toward the same direction), thereby improving the construction quality and reducing or even eliminating the stepping of the solid wood (bamboo) floor. The possibility of ringing.

Tiles: If the citizens’ new homes are floor tiles, it is best to route the pipes. The role of the line tube is not only to protect the wire, it also has the function to facilitate the replacement of the wire.

The connection between the cassette and the line tube: The cassette and the line tube are not connected with the mother of the lock. This is the most frequently found on the construction site. Some sites are all not installed, and some are partially loaded and some are missing. If you find that there is no equipment in the decoration, it means that the electrician has changed, and part of the equipment has been leaked. You need to raise it with the project manager. The electrician must be careful.

If the circuit in your home is found to have such a situation, it is recommended that you carefully and thoroughly check the circuit. This is not an electrician's job. It is the Andermen labor market who is looking for someone and giving him a pen is an electrician. That kind of people do it. Quickly examine the decorating company and see if it is a guerrilla that is full of intrigue.

According to the specification, the thickness of the protective layer of the pipeline buried in the wall should reach 10mm. We often see shallow grooves on some construction sites, and there are still some pipelines exposed outside with cement. These are all wrong. Not only is the depth of groove not enough, and the width is not enough. The three pipes are stacked together. It is difficult to make the wall surface flat in the future.

Hydropower renovation entrance decoration children's room decoration socket switch electrical lighting interior decoration living room wall color decoration living room floor tile bathroom design bathroom floor tile bathroom door decoration home bedroom decoration home bedroom lamp

1 23 Next> Total 3 Pages
Page to page
Function assignPage() { var page = $('#page_val').val(); if (/_\d+\.html$/.test(location.href)) { location.href = location.href.replace( /_\d+\.html/, ((page == 1) && 1? '' : '_' + page) + '.html') } else if(/\/\d+\.html$/.test (location.href)) { location.href = location.href.replace(/(\d+)\.html/, ((page == 1) && 1? '$1' :'$1_' + page) + ' .html') } } $(function(){ $('#page_form').submit(function() { assignPage() return false; }) $('#page_btn').click(function(){ assignPage( ); return false; }) }) See full story